Moderate slope · Caution

27.5° Roof Pitch

A 27.5° roof rises 521 mm for every metre of horizontal run, which is 6.25 in 12 in imperial terms (closest standard pitch 6/12). Its roof area multiplier is 1.127, so every square metre of plan area becomes 1.127 m² of roof surface.

27.50°run 1,000 mmrise 521 mm
Angle27.50°
Slope52.1%
Area multiplier1.127
Rise per metre521 mm
Imperial pitch6.25/12
Hip/valley per ft of run18.08 in

Rafter length for a 27.5° pitch

Multiply the horizontal run by 1.127. Add the overhang (horizontal overhang × 1.127) and deduct half the ridge board thickness.

Building spanRun (½ span)Common rafterRidge rise
4 m2 m2.25 m1.04 m
6 m3 m3.38 m1.56 m
8 m4 m4.51 m2.08 m
10 m5 m5.64 m2.60 m
12 m6 m6.76 m3.12 m

Gable roof, metric. Rafter length is measured along the slope from wall plate to ridge centre line, before eave overhang and ridge board deduction.

Building spanRun (½ span)Common rafterRidge rise
12 ft6 ft6 ft 9¼ in3 ft 1½ in
16 ft8 ft9 ft 0¼ in4 ft 2 in
20 ft10 ft11 ft 3¼ in5 ft 2½ in
24 ft12 ft13 ft 6¼ in6 ft 3 in
28 ft14 ft15 ft 9½ in7 ft 3½ in
32 ft16 ft18 ft 0½ in8 ft 4 in
36 ft18 ft20 ft 3½ in9 ft 4½ in
40 ft20 ft22 ft 6½ in10 ft 5 in

Gable roof, imperial. Rafter length is measured along the slope from wall plate to ridge centre line, before eave overhang and ridge board deduction.

Roof area at 27.5°

Roof surface area = plan area × 1.127. Use the roof calculator for multi-section roofs, waste and material costs.

Plan areaRoof surfaceWith 10% waste
80 m²90.2 m²99.2 m²
100 m²112.7 m²124.0 m²
150 m²169.1 m²186.0 m²
200 m²225.5 m²248.0 m²
250 m²281.8 m²310.0 m²

Plan area is the footprint measured to the outside of the eaves. Multiply by 1.127 for the sloped surface.

Plan areaRoof surfaceSquares (+10%)Shingle bundles
1,000 sq ft1,127 sq ft12.438
1,500 sq ft1,691 sq ft18.656
2,000 sq ft2,255 sq ft24.875
2,500 sq ft2,818 sq ft31.094
3,000 sq ft3,382 sq ft37.2112

Plan area includes eave overhangs. Bundles assume 3 bundles per square (100 sq ft) with 10% waste; hips, valleys and dormers need more.

Roofing materials for a 27.5° pitch (Australia & UK)

Typical manufacturer minimums. Check the specific product, sheet thickness, rafter length and exposure before ordering.

Roofing systemAt this pitchNotes
Concealed-fix steel deck (e.g. Lysaght Klip-Lok 700)Meets the typical 1° minimum1° applies to thicker sheet; 0.42 BMT is generally 2°.
Trapezoidal steel sheet (e.g. Lysaght Trimdek)Meets the typical 2° minimum—
Corrugated steel sheet (e.g. Lysaght Custom Orb)Meets the typical 5° minimum—
Interlocking concrete or terracotta tilesMeets the typical 15° minimumProfile dependent; many UK interlocking tiles need 17.5°–22.5°.
Natural slateMeets the typical 20° minimumTypical for larger slates; smaller slates and exposed sites need steeper pitches.
Plain tiles (clay or concrete)Below the typical 35° minimumSome products allow 30°.
Flat-roof membranes (EPDM, single-ply, felt)Usually reserved for flat and low-slope roofsDesigned for a finished fall of about 1:80 (0.7°) or more.

Roofing materials for a 27.5° pitch (US & Canada)

Minimum slopes from the 2021 International Residential Code. Canadian codes and manufacturers use similar limits for shingles and metal. Minimum pitch by material →

Roofing systemAt this pitchCode section
Asphalt shinglesMeets the 2/12 minimumIRC R905.2.2
Clay & concrete tileMeets the 2½/12 minimumIRC R905.3.2
Metal roof shinglesMeets the 3/12 minimumIRC R905.4.2
Slate & slate-type shinglesMeets the 4/12 minimumIRC R905.6.2
Wood shingles & shakesMeets the 3/12 minimumIRC R905.7.2 / R905.8.2
Standing-seam metal panelsMeets the ¼/12 minimumIRC R905.10.2
Lapped (exposed-fastener) metal panelsMeets the ½/12 minimumIRC R905.10.2
Mineral-surfaced roll roofingMeets the 1/12 minimumIRC R905.5.2
Membranes (TPO, EPDM, modified bitumen, built-up)Allowed, but normally used on low-slope roofsIRC R905.9–R905.13

Is a 27.5° roof steep?

Moderate pitches suit nearly every residential roofing material, shed water and snow well, and keep labour costs low because the roof is still workable.

A 27.5° roof is walkable for experienced roofers, but footing gets less forgiving on dew, dust or loose granules. Plan fall protection before going up.

27.5° roof pitch FAQ

What is a 27.5 degree roof pitch as a ratio?

27.5° is a rise of 6.25 in 12, closest to a standard 6/12 pitch. In metric that is 521 mm of rise per metre of run, or a slope of 52.1%.

How long is a rafter on a 27.5° roof?

Divide the horizontal run by cos 27.5°, which is the same as multiplying it by 1.127. On an 8 m wide building with a gable roof (4 m run), the rafter is 4.51 m before the eaves overhang.

How high is the ridge on a 27.5° roof?

Ridge height above the wall plate is the run × tan 27.5° (0.521). For an 8 m span (4 m run) that is 2.08 m.

Which roofing materials suit a 27.5° pitch?

27.5° meets the typical minimum for concealed-fix steel deck, trapezoidal steel sheet, corrugated steel sheet, interlocking concrete or terracotta tiles and natural slate. It is below the usual minimum for plain tiles. Minimums vary by product, sheet thickness, rafter length and exposure, so confirm with the manufacturer and local regulations.

Can you walk on a 27.5° roof?

A 27.5° roof is walkable for experienced roofers, but footing gets less forgiving on dew, dust or loose granules. Plan fall protection before going up.