Low slope · Walkable

2/12 Roof Pitch

A 2/12 roof rises 2 inches for every 12 inches of horizontal run. That is a 9.46° angle, a grade of 16.7% and a roof area multiplier of 1.014, so every square foot of plan area becomes 1.014 square feet of roof surface.

9.46°run 12rise 2
Angle9.46°
Slope16.7%
Area multiplier1.014
Rise per metre167 mm
Rafter per ft of run12.17 in
Hip/valley per ft of run17.09 in

Rafter length for a 2/12 pitch

Multiply the horizontal run by 1.014. Every foot of run needs 12.17 inches of common rafter. Add the overhang (horizontal overhang × 1.014) and deduct half the ridge board thickness.

Building spanRun (½ span)Common rafterRidge rise
12 ft6 ft6 ft 1 in1 ft 0 in
16 ft8 ft8 ft 1¼ in1 ft 4 in
20 ft10 ft10 ft 1¾ in1 ft 8 in
24 ft12 ft12 ft 2 in2 ft 0 in
28 ft14 ft14 ft 2¼ in2 ft 4 in
32 ft16 ft16 ft 2¾ in2 ft 8 in
36 ft18 ft18 ft 3 in3 ft 0 in
40 ft20 ft20 ft 3¼ in3 ft 4 in

Gable roof, imperial. Rafter length is measured along the slope from wall plate to ridge centre line, before eave overhang and ridge board deduction.

Building spanRun (½ span)Common rafterRidge rise
4 m2 m2.03 m0.33 m
6 m3 m3.04 m0.50 m
8 m4 m4.06 m0.67 m
10 m5 m5.07 m0.83 m
12 m6 m6.08 m1.00 m

Gable roof, metric. Rafter length is measured along the slope from wall plate to ridge centre line, before eave overhang and ridge board deduction.

Roof area at 2/12

Roof surface area = plan area × 1.014. Use the roof calculator for multi-section roofs, waste and material costs.

Plan areaRoof surfaceSquares (+10%)Shingle bundles
1,000 sq ft1,014 sq ft11.234
1,500 sq ft1,521 sq ft16.751
2,000 sq ft2,028 sq ft22.367
2,500 sq ft2,534 sq ft27.984
3,000 sq ft3,041 sq ft33.5101

Plan area includes eave overhangs. Bundles assume 3 bundles per square (100 sq ft) with 10% waste; hips, valleys and dormers need more.

Plan areaRoof surfaceWith 10% waste
80 m²81.1 m²89.2 m²
100 m²101.4 m²111.5 m²
150 m²152.1 m²167.3 m²
200 m²202.8 m²223.0 m²
250 m²253.4 m²278.8 m²

Plan area is the footprint measured to the outside of the eaves. Multiply by 1.014 for the sloped surface.

Roofing materials for a 2/12 pitch (US & Canada)

Minimum slopes from the 2021 International Residential Code. Canadian codes and manufacturers use similar limits for shingles and metal. Minimum pitch by material →

Roofing systemAt this pitchCode section
Asphalt shinglesAllowed — double underlayment required below 4/12IRC R905.2.2
Clay & concrete tileBelow the 2½/12 minimumIRC R905.3.2
Metal roof shinglesBelow the 3/12 minimumIRC R905.4.2
Slate & slate-type shinglesBelow the 4/12 minimumIRC R905.6.2
Wood shingles & shakesBelow the 3/12 minimumIRC R905.7.2 / R905.8.2
Standing-seam metal panelsMeets the ¼/12 minimumIRC R905.10.2
Lapped (exposed-fastener) metal panelsAllowed — only with applied lap sealant below 3/12IRC R905.10.2
Mineral-surfaced roll roofingMeets the 1/12 minimumIRC R905.5.2
Membranes (TPO, EPDM, modified bitumen, built-up)Meets the ¼/12 minimumIRC R905.9–R905.13

Roofing materials for a 2/12 pitch (Australia & UK)

Typical manufacturer minimums. Check the specific product, sheet thickness, rafter length and exposure before ordering.

Roofing systemAt this pitchNotes
Concealed-fix steel deck (e.g. Lysaght Klip-Lok 700)Meets the typical 1° minimum1° applies to thicker sheet; 0.42 BMT is generally 2°.
Trapezoidal steel sheet (e.g. Lysaght Trimdek)Meets the typical 2° minimum—
Corrugated steel sheet (e.g. Lysaght Custom Orb)Meets the typical 5° minimum—
Interlocking concrete or terracotta tilesBelow the typical 15° minimumProfile dependent; many UK interlocking tiles need 17.5°–22.5°.
Natural slateBelow the typical 20° minimumTypical for larger slates; smaller slates and exposed sites need steeper pitches.
Plain tiles (clay or concrete)Below the typical 35° minimumSome products allow 30°.
Flat-roof membranes (EPDM, single-ply, felt)Meets the typical 0.7° minimumDesigned for a finished fall of about 1:80 (0.7°) or more.

Is a 2/12 roof steep?

Low-slope roofs drain slowly, so most shingles and tiles are excluded or need extra underlayment. Membranes, standing-seam metal and roll roofing are the usual choices.

A 2/12 roof is walkable for most people in dry conditions with soft-soled footwear.

2/12 roof pitch FAQ

What is a 2/12 roof pitch in degrees?

A 2/12 pitch is 9.46°. It rises 2 inches per 12 inches of run, so the angle is arctan(2 ÷ 12). As a percentage that is a slope of 16.7%, and in metric it rises 167 mm per metre.

What is the roof pitch multiplier for 2/12?

The 2/12 multiplier is 1.014. Multiply the roof's plan (footprint) area by 1.014 to get the sloped surface area. A 2,000 sq ft plan area, for example, is 2,028 sq ft of roof before waste.

How do I calculate rafter length for a 2/12 pitch?

Multiply the horizontal run by 1.014. Each foot of run needs 12.17 inches of rafter, so a 24 ft wide gable (12 ft run) needs a common rafter of about 12 ft 2 in before adding the overhang and deducting half the ridge board. Hip and valley rafters on a regular hip roof need 17.09 inches per foot of common run.

Can you walk on a 2/12 roof?

A 2/12 roof is walkable for most people in dry conditions with soft-soled footwear. OSHA (29 CFR 1926.500) treats any roof steeper than 4/12 as a steep roof for fall protection purposes.

What roofing materials can go on a 2/12 pitch?

Under the US International Residential Code a 2/12 pitch meets the minimum slope for standing-seam metal panels, mineral-surfaced roll roofing and membranes (TPO, EPDM, modified bitumen, built-up). Asphalt shingles: allowed, but double underlayment required below 4/12. Lapped (exposed-fastener) metal panels: allowed, but only with applied lap sealant below 3/12. It is too shallow for clay & concrete tile, metal roof shingles, slate & slate-type shingles and wood shingles & shakes. Always check the manufacturer's installation instructions and your local code.