Moderate slope · Walkable

17.5° Roof Pitch

A 17.5° roof rises 315 mm for every metre of horizontal run, which is 3.78 in 12 in imperial terms (closest standard pitch 4/12). Its roof area multiplier is 1.049, so every square metre of plan area becomes 1.049 m² of roof surface.

17.50°run 1,000 mmrise 315 mm
Angle17.50°
Slope31.5%
Area multiplier1.049
Rise per metre315 mm
Imperial pitch3.78/12
Hip/valley per ft of run17.39 in

Rafter length for a 17.5° pitch

Multiply the horizontal run by 1.049. Add the overhang (horizontal overhang × 1.049) and deduct half the ridge board thickness.

Building spanRun (½ span)Common rafterRidge rise
4 m2 m2.10 m0.63 m
6 m3 m3.15 m0.95 m
8 m4 m4.19 m1.26 m
10 m5 m5.24 m1.58 m
12 m6 m6.29 m1.89 m

Gable roof, metric. Rafter length is measured along the slope from wall plate to ridge centre line, before eave overhang and ridge board deduction.

Building spanRun (½ span)Common rafterRidge rise
12 ft6 ft6 ft 3½ in1 ft 10¾ in
16 ft8 ft8 ft 4¾ in2 ft 6¼ in
20 ft10 ft10 ft 5¾ in3 ft 1¾ in
24 ft12 ft12 ft 7 in3 ft 9½ in
28 ft14 ft14 ft 8¼ in4 ft 5 in
32 ft16 ft16 ft 9¼ in5 ft 0½ in
36 ft18 ft18 ft 10½ in5 ft 8 in
40 ft20 ft20 ft 11¾ in6 ft 3¾ in

Gable roof, imperial. Rafter length is measured along the slope from wall plate to ridge centre line, before eave overhang and ridge board deduction.

Roof area at 17.5°

Roof surface area = plan area × 1.049. Use the roof calculator for multi-section roofs, waste and material costs.

Plan areaRoof surfaceWith 10% waste
80 m²83.9 m²92.3 m²
100 m²104.9 m²115.3 m²
150 m²157.3 m²173.0 m²
200 m²209.7 m²230.7 m²
250 m²262.1 m²288.3 m²

Plan area is the footprint measured to the outside of the eaves. Multiply by 1.049 for the sloped surface.

Plan areaRoof surfaceSquares (+10%)Shingle bundles
1,000 sq ft1,049 sq ft11.535
1,500 sq ft1,573 sq ft17.352
2,000 sq ft2,097 sq ft23.170
2,500 sq ft2,621 sq ft28.887
3,000 sq ft3,146 sq ft34.6104

Plan area includes eave overhangs. Bundles assume 3 bundles per square (100 sq ft) with 10% waste; hips, valleys and dormers need more.

Roofing materials for a 17.5° pitch (Australia & UK)

Typical manufacturer minimums. Check the specific product, sheet thickness, rafter length and exposure before ordering.

Roofing systemAt this pitchNotes
Concealed-fix steel deck (e.g. Lysaght Klip-Lok 700)Meets the typical 1° minimum1° applies to thicker sheet; 0.42 BMT is generally 2°.
Trapezoidal steel sheet (e.g. Lysaght Trimdek)Meets the typical 2° minimum—
Corrugated steel sheet (e.g. Lysaght Custom Orb)Meets the typical 5° minimum—
Interlocking concrete or terracotta tilesMeets the typical 15° minimumProfile dependent; many UK interlocking tiles need 17.5°–22.5°.
Natural slateBelow the typical 20° minimumTypical for larger slates; smaller slates and exposed sites need steeper pitches.
Plain tiles (clay or concrete)Below the typical 35° minimumSome products allow 30°.
Flat-roof membranes (EPDM, single-ply, felt)Usually reserved for flat and low-slope roofsDesigned for a finished fall of about 1:80 (0.7°) or more.

Roofing materials for a 17.5° pitch (US & Canada)

Minimum slopes from the 2021 International Residential Code. Canadian codes and manufacturers use similar limits for shingles and metal. Minimum pitch by material →

Roofing systemAt this pitchCode section
Asphalt shinglesAllowed — double underlayment required below 4/12IRC R905.2.2
Clay & concrete tileAllowed — double underlayment required below 4/12IRC R905.3.2
Metal roof shinglesMeets the 3/12 minimumIRC R905.4.2
Slate & slate-type shinglesBelow the 4/12 minimumIRC R905.6.2
Wood shingles & shakesMeets the 3/12 minimumIRC R905.7.2 / R905.8.2
Standing-seam metal panelsMeets the ¼/12 minimumIRC R905.10.2
Lapped (exposed-fastener) metal panelsMeets the ½/12 minimumIRC R905.10.2
Mineral-surfaced roll roofingMeets the 1/12 minimumIRC R905.5.2
Membranes (TPO, EPDM, modified bitumen, built-up)Allowed, but normally used on low-slope roofsIRC R905.9–R905.13

Is a 17.5° roof steep?

Moderate pitches suit nearly every residential roofing material, shed water and snow well, and keep labour costs low because the roof is still workable.

A 17.5° roof is walkable for most people in dry conditions with soft-soled footwear.

17.5° roof pitch FAQ

What is a 17.5 degree roof pitch as a ratio?

17.5° is a rise of 3.78 in 12, closest to a standard 4/12 pitch. In metric that is 315 mm of rise per metre of run, or a slope of 31.5%.

How long is a rafter on a 17.5° roof?

Divide the horizontal run by cos 17.5°, which is the same as multiplying it by 1.049. On an 8 m wide building with a gable roof (4 m run), the rafter is 4.19 m before the eaves overhang.

How high is the ridge on a 17.5° roof?

Ridge height above the wall plate is the run × tan 17.5° (0.315). For an 8 m span (4 m run) that is 1.26 m.

Which roofing materials suit a 17.5° pitch?

17.5° meets the typical minimum for concealed-fix steel deck, trapezoidal steel sheet, corrugated steel sheet and interlocking concrete or terracotta tiles. It is below the usual minimum for natural slate and plain tiles. Minimums vary by product, sheet thickness, rafter length and exposure, so confirm with the manufacturer and local regulations.

Can you walk on a 17.5° roof?

A 17.5° roof is walkable for most people in dry conditions with soft-soled footwear.